request for gen_vel to work with multiple temperature coupling groups at different temperatures - Redmine #1026
Archive from user: Chris Neale
The output of grompp from v4.5.5 suggests that gen_vel only uses the first value given, although there is no error if multiple temperatures are listed. i.e. if I supply two temperatures to gen_vel, then I only get one message "Velocitied were taken from a Maxwell distribution at X K, where X is the first listed temperature.
Perhaps this is just an output issue with gromp I was using the sd integrator.
(from redmine: issue id 1026, created on 2012-10-30 by gmxdefault)
- Relations:
- relates #1893 (closed)