Skip to content

TOP-993: create correlator output

Deneys Maartens requested to merge top-1062-corr-output into main

This implements the ITC.L.AA0.5.CORR.1 Single scan data path test.

The test spec calls for a 90 sec integration. This results in a ~15 min CD/CD pipeline duration. Some logic has been added to limit scan duration to 5 seconds, or 5 integration periods, depending on which is requested.

Edited by Deneys Maartens

Merge request reports