Sensor_Humidity: HDC1080: disconnect DAP (EP)
From the device datasheet (https://www.ti.com/lit/ds/symlink/hdc1080.pdf): "DAP - Die Attach Pad. Should be left floating." "The DAP may be soldered to a floating pad on the board, but the board pad should NOT be connected to GND."
All contributions to the kicad library must follow the KiCad library convention
Thanks for creating a pull request to contribute to the KiCad libraries! To speed up integration of your PR, please check the following items:
-
Provide a URL to a datasheet for the symbol(s) you are contributing -
An example screenshot image is very helpful -
Ensure that the associated footprints match the official footprint library - A new fitting footprint must be submitted if the library does not yet contain one.
-
If there are matching footprint PRs, provide link(s) as appropriate -
Check the output of the Travis automated check scripts - fix any errors as required -
Give a reason behind any intentional library convention rule violation.
Thanks!