Add: Wuerth 7999010211A RJ45 magjack
This adds the Wuerth 7999010211A RJ45 magjack
https://www.we-online.com/components/products/datasheet/7499010211A.pdf
Pad is radius 1.2, so courtyard is >=1.7
WE STEP:
Download_STP_7499010211A_rev1.stp / https://www.we-online.com/components/products/download/7499010211A%20%28rev1%29.stp
Keepouts
Keepouts are added to avoid accidental contact between the shield and vias, tracks, etc.
The shield "danger zone" by the locating pins is (per the 3D model, which looks very like the physical part) 1.90mm on each side, and do not reach the pin midline:
So adding 0.25mm clearance:
The shield at the front extends inwards 2.70mm:
Add a clearance that should always be a safe keepout (the nodes are on the 0.1mm grid, but the fab outline is not, so it doesn't have a round number, but it's not a critical value as long as it's safe)