PCB Cleanup - cleans inappropriate things when zones haven't been filled (or fills aren't up-to-date)
In Jenkins 2020-08-12 (and prior version) PCB Cleanup, Deselecting "Del Redundant Vias" does NOT prevent redundant vias from being deleted.
I'm doing an RF pcb with lots of ground stitching. I want to do a cleanup, including Dangling Tracks. Regardless of the Via selection, the vias all get DEL if "Dangling Tracks" is Selected. Perhaps vias are confused with dangling tracks?
refs: #2485 (closed)
https://forum.kicad.info/t/pcb-cleanup-deletes-redundant-vias-when-not-checked/24356/2
Update: deleted reference to 5.99 as it was incorrect. apologies to paulvdh