Rename eeschema simulation bode export titles
Description
When doing AC analysis and trying to plot the bode yourself numerically, something interesting starts happening, it does plot like ltspice or others, but the titles are a bit off. when exporting.
Steps to reproduce
- create a PI filter in eeschema or anything
- do AC analysis
- export the values and plot them with matplotlib.
Kicad simulation interface looks like this but
the titles are frequency;V(/pifilter/aus)5;V(/pifilter/aus)9;
what does 5 and 9 mean? why not _dB or _arg? or _deg
pi_filter_sim_kicad.csv I will gladly provide the project in case it is relevant, but I don't think it is relevant.
KiCad Version
Application: x64 on x64
Version: 8.0.0, release build
Libraries:
wxWidgets 3.2.4
FreeType 2.13.2
HarfBuzz 8.3.0
FontConfig 2.15.0
libcurl/8.6.0 OpenSSL/3.2.1 (Schannel) zlib/1.3.1 brotli/1.1.0 zstd/1.5.5 libidn2/2.3.7 libpsl/0.21.5 libssh2/1.11.0 nghttp2/1.59.0
Platform: Windows 8.1 (build 9600), 64-bit edition, 64 bit, Little endian, wxMSW
Build Info:
Date: Mar 1 2024 18:38:47
wxWidgets: 3.2.4 (wchar_t,STL containers)
Boost: 1.84.0
OCC: 7.7.2
Curl: 8.6.0
ngspice: 42
Compiler: GCC 13.2.0 with C++ ABI 1018
Build settings: