feat(config): rate_limit configuration block (S05-B plan: 4/4)

Summary

Step 4 of the S05-B plan: the rate_limit configuration block from S05-B's Configuration. The proto gains the RateLimit, RateLimitOverride, and RateLimitConfig messages and Config.rate_limit (field 24); internal/config/ratelimit.go converts the block into the config-owned runtime types (Mode defaulting to observe, the one-second period floor, UUID-keyed overrides); and config.example.yaml and docs/dev/configuration-reference.md document the block as-is.

No consumer reads the block: the mount on the six pull arms lands with #1181's plan, so a declared limit refuses no request, adds no header, and is counted nowhere until then.

Where the spec's proto snippet says "shared by every arm", the shipped proto and example comments read "which every arm will share": writing-discipline requires future tense for relationships to parts that have not landed, so the code comments carry it and the spec's own wording stays with its author.

Governing ADRs

ADR-004 (Rate Limits): rate-limit configuration lives in the service's own config, applied at the next rollout; per-namespace overrides are a first-class config property; observe, warn, and enforce match the rollout strategy; and the namespace class is first, matching the closed namespace-only key set. The known deviation from ADR-004's IP-first rollout sentence (namespace-first key order) is already escalated in handbook MR !21345. Checked against the ADR index; no other ADR touches this change.

Plan and spec amendments

Step 4's Tests entry named only internal/config/ratelimit_test.go. It now also names internal/config/ratelimit_internal_test.go, the in-package test reaching the override-key parse arm that protovalidate's map-key rule makes unreachable through Load.

S05-B's Error Cases table was silent on two spellings of one namespace UUID in namespace_overrides. The proto's map-key rule accepts either case, so both spellings load as distinct keys that uuid.Parse folds onto one, where the second write would replace the first; the loader now rejects the pair, and the table gains the row.

S05-B's Configuration section claimed a limits typo "cannot silently disable a limit". The loader is non-strict, so only a misspelled limiter name fails startup; a misspelled section or field name is dropped silently. The sentence now says which typo fails, and the configuration reference documents the dropped keys.

All three corrections ride this MR rather than a separate amendment MR per review-driven plan corrections: they correct the step's own text and the spec clauses governing its code, and change no step boundary.

Testing

Unit tests in internal/config/ratelimit_test.go (external package, through config.Load) and internal/config/ratelimit_internal_test.go (in-package, reaching the override-key parse arm Load cannot).

Spec coverage: S05-B acceptance criterion 14 and the configuration rows of S05-B's Error Cases.

Case Tests
AC-14: omitted mode converts to observe TestLoad_RateLimit_Mode
AC-14: period below one second rejected TestLoad_RateLimit_PeriodBelowOneSecondRejected, TestLoad_RateLimit_PeriodUnparseable, TestLoad_RateLimit_EmptyPeriodRejected
Closed limits key set TestLoad_RateLimit_LimitsKeyOutsideClosedSetRejected
Override key not a UUID TestLoad_RateLimit_OverrideKeyNotUUIDRejected, TestRateLimitOverridesFromProto_RejectsMalformedKey
Two spellings of one namespace UUID TestLoad_RateLimit_OverrideDuplicateNamespaceRejected, TestRateLimitOverridesFromProto_RejectsCaseFoldedDuplicate
Mode outside the proto in set rejected TestLoad_RateLimit_ModeOutsideSetRejected
Non-positive rate or burst, base and override TestLoad_RateLimit_NonPositiveRateOrBurstRejected, TestLoad_RateLimit_OverrideNonPositiveRateOrBurstRejected
Omitted or empty block wires no limits TestLoad_RateLimit_OmittedOrEmptyBlockWiresNoLimits
Every field round-trips TestLoad_RateLimit_HappyPath, TestLoad_RateLimit_Period
Exported zero values TestRateLimit_ZeroValue
Example block pinned and parsed TestLoad_RateLimit_ConfigExampleDefault

TestRateLimit_ZeroValue pins the exported zero-value contract (internal/AGENTS.md): RateLimitConfig{} wires no limiter, and RateLimit{} carries Mode "", not observe — only a loaded config selects observe. TestRateLimitOverridesFromProto_RejectsMalformedKey drives the second-layer override-key parse directly, the only way to reach the arm: through Load, the proto's map-key UUID rule rejects the key first.

e2e scenario impact: none. This step mounts no consumer, so no externally observable behavior changes; the e2e rows for a served 429 belong to #1181's mount plan.

docs/user impact: none. Every surface this step ships is inert until the mount: no request is refused, warned, or headered, and the one published sentence touching rate limits (docs/user/_index.md) already states the enforcement posture this step leaves unchanged. The user-facing rate-limit page lands with the mount's plan.

Size

The diff is 806 reviewable lines (added plus removed, excluding the regenerated config.pb.go), above the 500-line guideline:

File group Lines
Loader: internal/config/ratelimit.go, internal/config/config.go 182
Tests: internal/config/ratelimit_test.go, internal/config/ratelimit_internal_test.go 493
Plan: docs/plans/2026-10-05-s05b-rate-limiting.md 8
Schema: proto/artifactregistry/config/v1/config.proto 68
Operator docs: config.example.yaml, docs/dev/configuration-reference.md 55

A split would not help review: the schema, the loader that enforces it, and the tests that pin its rejection arms are one reviewable unit from one spec section, and splitting the test file from the loader it pins would spread one review across two MRs without shrinking either.

Related to #1181

Edited by Moaz Khalifa

Merge request reports

Loading
Loading