Actuator connected to hydraulic line from hydraulic panel not supported
Created by: PaulSnijder
Hydraulic line connected to nozzle of hydaulic panel. Control Valve and Actuator in loop. But no Process Information Function, so no owner available. How to model? Can proviide example ppt