report fail logic test CD40106
I was repairing an infrared barrier that does not work, it has a HEF400106BP DIP14, I checked it and he gave me that he has 12 erros, so I tried a new one CD40106BP and gave me that it has 6 errors, I put the integrated new in the board and walked the infrared barrier.
HFE40106BP DIP14 (bad) NXP
$ minipro -T -p 40106
Found TL866II+ 04.2.132 (0x284)
Device code: xxxxxxxx
Serial code: xxxxxxxxxxxxxxxxxxxx
1 2 3 4 5 6 7 8 9 10 11 12 13 14
0000: 0 H- 0 H- 0 H- G H- 0 H- 0 H- 0 V
0001: 1 L- 1 L- 1 L- G L- 1 L- 1 L- 1 V
Logic test failed: 12 errors encountered.
CD40106BE DIP14 (new) Texas (I have several of these new ones and everyone gives 6 errores)
$ minipro -T -p 40106
Found TL866II+ 04.2.132 (0x284)
Device code: xxxxxxxx
Serial code: xxxxxxxxxxxxxxxxxxxx
1 2 3 4 5 6 7 8 9 10 11 12 13 14
0000: 0 H 0 H 0 H G H 0 H 0 H 0 V
0001: 1 L- 1 L- 1 L- G L- 1 L- 1 L- 1 V
Logic test failed: 6 errors encountered.
With a similar SN74HC14N DIP14 (new) Texas
$ minipro -T -p 7414
Found TL866II+ 04.2.132 (0x284)
Device code: xxxxxxxx
Serial code: xxxxxxxxxxxxxxxxxxxx
1 2 3 4 5 6 7 8 9 10 11 12 13 14
0000: 0 H 0 H 0 H G H 0 H 0 H 0 V
0001: 1 L 1 L 1 L G L 1 L 1 L 1 V
Logic test successful.
I have the Xgpro V12.32 program and updated to firmware 0x284 (executing it under app-emulation/wine-staging-9.4.1) The question is: can I update the Xgpro program to its latest available version and to the firmware distributed with that version?
Greetings.
Edited by colo-des