Change ADConversion Filter to specify only relevant fields
The ADConversion Filter currently has the same fields as the Analog
Filter, plus input_full_scale
and output_full_scale
, but it doesn't check those values against the stage's gain. Unfortunately, gain is at another level, but maybe it should at least check the gain and give a warning if it's not correct? Also maybe add values that might be more accurate and allow binary notation (would have to be able to specify if it was signed or not) for the output_scale:
v_plus: 2.5
counts_plus: '7FFFFFFEh'
v_minus: -2.5
counts_minus: '80000001h'
counts_type: 'i32'