Commit 43849785 authored by Fabien Parent's avatar Fabien Parent Committed by Olof Johansson

ARM: dts: da850-evm: fix read access to SPI flash

Read access to the SPI flash are broken on da850-evm, i.e. the data
read is not what is actually programmed on the flash.
According to the datasheet for the M25P64 part present on the da850-evm,
if the SPI frequency is higher than 20MHz then the READ command is not
usable anymore and only the FAST_READ command can be used to read data.

This commit specifies in the DTS that we should use FAST_READ command
instead of the READ command.

Cc: [email protected]
Tested-by: Kevin Hilman's avatarKevin Hilman <[email protected]>
Signed-off-by: Fabien Parent's avatarFabien Parent <[email protected]>
[[email protected]: subject line adjustment]
Signed-off-by: default avatarSekhar Nori <[email protected]>
Signed-off-by: Olof Johansson's avatarOlof Johansson <[email protected]>
parent e47a8b17
......@@ -99,6 +99,7 @@ flash: [email protected] {
#size-cells = <1>;
compatible = "m25p64";
spi-max-frequency = <30000000>;
m25p,fast-read;
reg = <0>;
partition@0 {
label = "U-Boot-SPL";
......