postProc.exe error to 2 bodies using hydrosCal.exe
Hello people from Nemoh and everybody!
In the simulation of two submerged cylinders using NemohWrapper when I use ID_HydrosCal=0 no error occurs in my set of routines. But if ID_HydrosCal=1 (I want to calculate RAO) I receive that standard message, already reported in the closed and unresolved topic: "#40 (closed) posProc not working with 2 bodies", which in my understanding refers to a file missing or in an unknown directory: "At line 56 of file /builds/lheea/Nemoh/postProcessor/MPP_ReadInputFiles.f90 Fortran runtime error: End of file".
It seems to me that the problem would be hydrosCal.exe. So, please, could someone tell me if:
1 - Does hydrosCal.exe read the Mesh1.cal and Mesh2.cal files separately or will I have to send just one Mesh.cal with both cylinders?
2 - If it is just one mesh.cal file, what would its content be? If not, what should be the name of each file?
3 - Same for items 1 and 2 above, but for the other tec, dat etc two bodies files?
On page 10 of the Nemoh Manual, in item 2.3.2 NEMOH1: 1st-order solver, it is written that: "If the input mesh is generated by the NEMOH mesh preprocessor, mesh, the hydrostatic parameters are already computed and then it is not necessary to execute the program hydrosCal.exe."
4 - Can I have RAO with ID_HydrosCal=0?
Thank you.
Cadbufc.
Some files:output_files.rar.