Simulation starts surprisingly already when the 'Inspect->Simulator' button is hit
When a circuit has been simulated, all its data have been plotted and saved, and later it is reloaded into Eeschema by File -> Open Recent and then when I select from the Eeschema window Inspect -> Simulator the simulation starts immediately. This also happens when I just redo the simulation in the existing eeschema window.
This behaviour is somewhat surprising, and if the simulation takes more than a few seconds, the 'busy' sign as the only reaction in Eeschema is irritating (What is going on? Do I have a problem?). Only when the simulation has finished, the simulator window pops up.
I would prefer that after choosing Inspect -> Simulator, the simulator window always pops up first, and the simulation is started only after hitting the 'Run/Stop Simulation' button.
KiCad Version
Application: KiCad Schematic Editor (64-bit)
Version: (5.99.0-11076-g4c8a4e3d), release build
Libraries: wxWidgets 3.1.5 libcurl/7.74.0-DEV Schannel zlib/1.2.11
Platform: Windows 10 (build 19042), 64-bit edition, 64 bit, Little endian, wxMSW
Build Info: Date: Jun 18 2021 09:00:13 wxWidgets: 3.1.5 (wchar_t,STL containers) Boost: 1.75.0 OCC: 7.5.0 Curl: 7.74.0-DEV ngspice: 34 Compiler: Visual C++ 1928 without C++ ABI
Build settings: KICAD_USE_OCC=ON KICAD_SPICE=ON