Leap-frog Nose-Hoover fails the physical-validation ensemble check at the default nsttcouple

Summary

With integrator = md and tcoupl = nose-hoover, the default nsttcouple = -1 resolves to 25 for tau-t = 1 ps and dt = 2 fs. That is the coarsest interval c_minimumStepsPerPeriodNoseHoover = 20 allows, which became reachable when baf0d16d (GROMACS 2023) raised c_defaultNstTCouple from 10 to 100. At that interval, a water system fails the physical-validation ensemble check on every run. With nsttcouple = 1 it passes.

GROMACS version

main at dd6303bdf6 (2027.0-dev, built on a branch that only touches the GPU update path), single precision, -ntmpi 1 -ntomp 8 -nb gpu -pme gpu -update cpu.

Steps to reproduce

Copy tests/physicalvalidation/systems/ens_water_md_settle_pme_vr (900 TIP3P waters, SETTLE, PME, 500,000 steps at 2 fs) and change two mdp lines: tcoupl = nose-hoover and tau-t = 1.0 (up from 0.1, which is too short for Nose-Hoover). Leave nsttcouple unset. Run the same checks as the v-rescale system: ensemble -t 4 --dtemp 9 and kin_mb -t 0.01. For comparison, set nsttcouple = 1 or 10.

What is the current bug behavior?

nsttcouple Runs Ensemble check passes Quantiles off Fitted dT (true 9.0 K) Maxwell-Boltzmann passes
1 3 3/3 0.32, 0.39, 1.67 8.8 to 10.1 K 3/3 (p = 0.32 to 0.45)
10 3 2/3 2.64, 2.84, 4.97 6.9 to 7.7 K 3/3 (p = 0.28 to 0.54)
25 (default) 4 0/4 7.52, 9.42, 10.67, 13.01 5.0 to 6.1 K 2/4 (p = 0.00046 to 0.033)

What did you expect the correct behavior to be?

The default settings should pass, as they do for the v-rescale system.

Possible fixes

Should c_minimumStepsPerPeriodNoseHoover be raised for leap-frog, or should Nose-Hoover get a lower nsttcouple cap?