Ewald surface-epsilon is incorrect - Redmine #3441
The Ewald surface-epsilon correction term is incorrect when molecules
are broken over PBC.
It should be disabled in the 2020 release.
(from redmine: issue id 3441, created on 2020-03-11 by berkhess)
- Changesets:
- Revision c4878aff by Berk Hess on 2020-03-17T07:47:33Z:
Disable Ewald dipole correction without DD
Refs #3441
Change-Id: I492cd136b41e57b3e2198c1f0717177fb4d46a7c
- Revision 2548c9e0 by Berk Hess on 2020-03-18T22:04:44Z:
Use WholeMoleculeTransform for orires and epsilon-surface
Remove direct use of the graph from the orientation restraint
and Ewald epsilon-surface term code by passing in whole molecules
created by the WholeMolecules class.
Since this was the only remaining use of graph in do_force(),
it can now be removed.
Also enabled the epsilon-surface mdrun-test.
Fixes #3441