Notes by Agnieszka Plonczak about the Farm Process
-
The input the FID and CID files generated by FREEWAT, in case when the farm or crop number is more that one digit, is not readable by MODFLOW, cause the are no spaces between the numbers.
-
PSI.in, the psi1 values are always set to "0" in the input file, even though they have a different value in the Crop Table. This change influence the transpiration rate.
-
OFE.in file seems not to be correctly written in case of 25 crop types and 12 stress periods. The file created by FREEWAT had 12 values in each row. MODFLOW was able to read the OFE.in only when the User increased the number of records in the row to 25. In general, OFE.in should be "In matrix form (NFARMS = number of farms; NCROPS = number of crops):".