Light Curves (Auto/Manu) calculation issue
Siril version: master
By comparing the Auto mode and the Manual modes to generate 2 light curves, a strange dependancy (I can't explain up till now) accured.
If the number of pictures discarded because of Photometry analysis failed for image 77 (pixel out of range)
(as an example), the 2 LC generated will be different.
As an example, see on the left a LC from an AUTO process, and on the right, the same one with a Manual process (same comp stars).
Remarks:
- If this number of discarded images is 0, the 2 curves are identical
- The Auto LC is insensitive to the number of discarded images
We have a diffrence between the 2 processes, and we should not.
This issue comes in addition to #1169 (closed)
EDIT: here is an additional clue:
After the V star photometric analysis, a number of images are discarded with failure. OK, this is the starting point of the issue.
- if you open the frame list, these images are not set as discarded. And so, the futur LC calculation can be faulty.
- on the other and, if you manually uncheck these images (to set them as discarded), the 2 light curves will be the same.
Edited by Fred DJN