C++ fleet client never sends: start() spawns no heartbeat/controller thread (Python parity)
Summary
The C++ variant of the fleet client never transmits anything. StatusMonitor::start() / FleetMonitorClient::start() are effectively no-ops — they record start_time and clear the stop flag but spawn no background thread, and the one method that actually sends (StatusMonitor::sendAll() → FleetMonitorClient::sendHeartbeat()/sendDiagnostics()) is never called anywhere in the C++ tree.
Result: a consuming app logs "Fleet reporting started" but zero heartbeats/diagnostics/status reach fleet.brinkhaus-gmbh.de, with no error (because post() is never reached).
The Python variant is correct — its start() methods spawn the background loops. This is a behavioral parity bug in the C++ port; the wire protocol/payloads are fine.
Evidence
- Real consumer: DigitalWay
samplingbackend, customerdw, machinetest. - Server-side (
ssh root@berlin,docker logs fleetmanager): 0POST /api/ingest/dw/...in 3h and over a 75s live tail, while other customers (gmn/brinkhaus/uttec) send 200 OK continuously. Thedw/testinstance shows RED/overdue. - A manual
curl POST /api/ingest/dw/test/samplingbackend/heartbeatwith the real bearer token returned{"ok":true}200 and turned the machine green → token, customer, path and server are all fine. Only the C++ client doesn't send.
Root cause (C++ vs Python)
| Aspect | Python (correct) | C++ (broken) |
|---|---|---|
FleetMonitorClient.start() |
spawns _heartbeat_loop thread (python/.../fleet/client.py:146-158) + sends initial status=running |
only sets start_time_, no thread (cpp/src/fleet_monitor_client.cpp:92-95) |
StatusMonitor.start() |
spawns _controller_loop thread → diagnostics+status every 60s (python/.../fleet/monitor.py:94-105) |
only calls client_->start() (cpp/src/status_monitor.cpp:54); sendAll() never invoked |
| connection state → diagnosis | _on_connection_change → notify/clear code 7002 (monitor.py:220) |
not wired |
| config retry | _try_reload_config (monitor.py:146) |
missing |
| initial/final status | running on start, stopped on stop |
none |
| TLS | urllib + default SSL ctx (verified, system/certifi CAs) |
libcurl without CURLOPT_CAINFO/SSL_VERIFYPEER (fleet_monitor_client.cpp:225-231) → may fail silently on Windows/OpenSSL builds |
Proposed fix (C++)
FleetMonitorClient::start(): spawn a heartbeat thread sending everyheartbeat_interval(mirror Python_heartbeat_loop); send initialrunningstatus.StatusMonitor::start(): spawn a controller thread sending diagnostics + snapshot/status every 60s, with config-retry, and mirror connection state intoSelfDiagnosisEngine(codes 7001 config-missing, 7002 connection-error).- Set
CURLOPT_CAINFOto a bundled CA (or build libcurl with Schannel) so HTTPS verification matches Python.
Keep the variants compatible (process)
The shared test-fixtures/ + schemas/ only validate payload shape, not runtime behavior — which is why this slipped through.
- Add a language-agnostic behavior spec (alongside
architecture/fleet-protocol.md):start()MUST start the send loop; intervals; diagnosis codes 7001/7002; initial/final status. Makestart()semantics explicit so a porter can't stub it. - Add a behavioral conformance test in CI for every variant: point the monitor at a mock ingest server, assert ≥1 heartbeat + diagnostics + status arrive within ~2× interval, schema-valid, correct path segments. (Would have caught this immediately.)
- Track behavior parity per variant in
docs/api-overview.mdand gate releases on it. - Designate Python as the reference implementation; behavior changes land in reference + spec + fixtures first, then ports.
Affected downstream
brinkhauslib / samplingBackend (Digital Way): fleet reporting silently does nothing. Workaround until fixed: call fleetMonitor->sendAll() on a 60s timer in the app, and set a real machineName (currently the placeholder your-machine-name).