Test Plan Reference: "Edit Parameter" works on a loaded parent step
Environment:
Windows 10, 64-bit
Test Automation 9.13.1 (reproduced on 9.9.3)
Steps to reproduce:
- Add a Test Plan Reference step
- Load attached test plan (SequenceWithDelay.TapPlan) in a Test Plan Reference
- Go to Sequence. Edit Parameter - > works
- Remove Time Delay setting from the parameter - > works
Actual result:
Expected result:
Loaded test plans should be locked
Other remarks:
Edited by Sebastian Vlaic