VEE shows Error 700 when called by CallableVEE
The code seems to run fine, it just has this error. Not sure if the same error happens with VEE Runtime? Is this only on @alan's laptop? Or does this happen on a fresh install of VEE 9.33?
Update 1/Workaround: The following registry key specifies the path to VEE and is used when creating the COM server.
HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Classes\CLSID{603F0662-3B96-11d2-9645-080009CB54BD}\LocalServer32
(Default) - C:\Program Files (x86)\Keysight\VEE Pro 9.3\vee.exe /Automation /CallServer
When I added quotes around the path, the error went away:
(Default) - "C:\Program Files (x86)\Keysight\VEE Pro 9.3\vee.exe" /Automation /CallServer
This key value should be "patched" when the TAP plugin is installed.
Edited by Brennen DiRenzo